Testing for Concrete Strength - GERMANN | Test Smart

Test smart – Build right Testing for Concrete Strength •Quality control and acceptance testing Standardized curing conditions Indicator of potential strength Code compliance •In-place strength Investigate low test results for standard-cured specimens (cylinders or cubes) Determine if constructions loads can be applied Evaluate existing structures

TEST ON HARDENED CONCRETE - SlideShare

1. COMPRESSION TEST. 14. • Compression test is the most common test conducted on hardened concrete, partly because it is an easy test to perform, and partly because most of the desirable characteristic properties of concrete are qualitatively related to its compressive strength.

Flow table test of concrete to test Workability of concrete

Procedure of flow table test: Prepare concrete as per mix design and place the flow table on a horizontal surface. Clean the dust or other gritty material on Flow table and Sprinkle a hand of water on it. Now place the metal cone at the middle portion of the flow table and stand on it. Pour the freshly mixed concrete in the mould comprising two ...

Topics in Concrete

The American Concrete Institute. Founded in 1904 and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensus-based standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete …

COMPRESSIVE STRENGTH OF CONCRETE - HARDENED …

Compressive Strength of Concrete IS 456 Interpretation of Test Results of Sample specified Grade Mean of the Group of 4 Non-Overlapping Consecutive Test Results In N/mm2 Individual Test Results In N/mm2 (1) (2) (3) M 20 > fck + 0.825 X established SD > fck -3 N/mm2 or above (rounded off to nearest 0.5 N/ mm2) Or fck + 3 N/mm2, whichever is greater

Concrete mix proportioning as per IS 10262:2009 ...

V = absolute volume of fresh concrete, which is equal to gross volume (m3) minus the volume of entrapped air, W = mass of water ( kg ) per m3 of concrete C = mass of cement ( kg ) per m3 of concrete S c = speciic gravity of cement, (p) = Ratio of fine aggregate to total aggregate by absolute volume, (f a), (c a) = total mass of fine aggregate ...

Aggregates for Concrete - Memphis

concrete volume (70% to 85% by mass) and strongly influ-ence the concrete's freshly mixed and hardened proper-ties, mixture proportions, and economy. Fine aggregates (Fig. 5-1) generally consist of natural sand or crushed stone with most particles smaller than 5 mm (0.2 in.). Coarse aggregates (Fig. 5-2) consist of one or a com-CHAPTER 5

Rebound Hammer Test | Schmidt's Hammer | A Non Destructive ...

A Non Destructive Test (NDT) is a way of testing a structural element without causing any destruction, there are two types of tests,1) Destructive Test2) Non...

IS 516 (1959): Method of Tests for Strength of Concrete

concrete work. Systematic testing of the raw materials, the fresh con­ crete and the hardened concrete is an inseparable part of any quality control programme for concrete which helps to achieve higher efficiency of the materials used and greater assurance of the performance of the concrete in regard to both strength and durability. The test ...

Concrete Slump Test Procedure, Applications & Types of Slump

Concrete Slump Test. The concrete slump test is used for the measurement of a property of fresh concrete. The test is an empirical test that measures the workability of fresh concrete. More specifically, it measures concrete consistency between batches. The test is popular due to the simplicity of apparatus used and simple procedure.

7 Lab Test on Aggregate Should Satisfy for Use in Concrete

As per the 'Fournier, B & Berube, M' (2011) (Published in: Alkali-aggregate reaction in concrete: A review of basic concepts and engineering implications), the alkali-aggregate reaction is the chemical reaction that occurs in the concrete which can produce the premature distress and loss in serviceability thereby, affecting concrete ...

CONCRETE MATERIALS AND TESTING - MnDOT

September 1, 2003 CONCRETE MAN UAL 5-694.100 CONCRETE MATERIALS AND TESTING 5-694.100 5-694.101 GENERAL REQUIREMENTS The Specifications contain requirements for all concrete materials. Inspect all materials used in the construction of concrete work at their source, on the job, or both. The Engineers and

Standard test on fresh concrete - SlideShare

Flow Test Conducting The flow table is wetted. The cone is placed on the flow table and filled with fresh concrete in two layers, each layer 25 times tamp with tamping rod. The cone is lifted, allowing the concrete to flow. The flow table is then …

Tests on Fresh Concrete | Protocol - JoVE

Our fresh concrete mix had a slump of 3.5 inches. In general, mixes such as the one described in this experiment have slumps of three to four inches. Such values are common for small jobs with little steel congestion in the forms. The unit weight of our concrete was 147 pounds per cubic foot.

Compressive Strength Test of Concrete - Civil Engineering ...

Depending on the applied code, the test sample may be cylinder [15 cm x 30 cm is common] or cube [15 cm x 15cm x 15 cm is the most common]. For example, as per ASTM C39, a standard test method is given to get the compressive strength of concrete cylinders. Compressive Strength Test Idea: 1- Concrete is poured in the mould and compacted properly ...

Test of concrete - SlideShare

TEST OF CONCRETE. 4. CONCRETE SLUMP TEST Theory and Scope:- The concrete slump test is an empirical test that measures the workability of fresh concrete. More specifically, it measures the consistency of the concrete in that specific batch. This test is performed to check the consistency of freshly made concrete.

principles of concrete mix design.ppt - ACC Help

Concrete Mix Design -Definition Concrete mix design is defined as the appropriate selection and proportioning of constituents to produce a concrete with pre-defined characteristics in the fresh and hardened states. In general, concrete mixes are designed in order to achieve a defined workability, strength and durability .

CEMENT and CONCRETE TECHNOLOGY

Knowledge Fresh and harden concrete properties Using concrete laboratory to find concrete properties Course Conduct: Midterm Exam ( 35 points), Assignments & Presentations (15 points ) and Final Exam (50 points). Course Outline: Introduction: constituents, history, advantages, limitations and applications. Aggregates: physical and mechanical ...

ASTM C138 - ACI Density, Yield, and Air Content of Concrete

This will not be on the test.) The yield per cubic yard in cu.ft./cu.yd. Yield per batch [result from (a)] / cu.yds delivered = yield per cu.yd. in cu.ft./cu.yd. Relative yield is the ratio of the actual volume of concrete obtained to the volume as designed for the batch. It is understood as a 1:1 ratio.

Concrete Testing Procedures - Tests for Slump & More ...

Air-entrained concrete is typically specified in areas of the country where frost-related damage can occur. The measurement of air content in fresh concrete of normal density is typically performed using the pressure method ().Another useful test is ASTM C 173.However, the pressure method is frequently preferred because it is relatively fast.

IS 4031-6 (1988): Methods of physical tests for hydraulic ...

2. SAMPLING AND SELECTION OF TEST SPECIMEN 2.1 The samples of the cement shall be taken in accordance with the requirements of IS: 3535­ 1986* and the relevant standard specification for the type of cement being tested. The representa­ tive sample of the cement selected as above shall be thoroughly mixed before 'testing,

Workability of Concrete - Tests & Factors Affecting ...

This test is best suitable for flowing concrete made by the use of superplasticizing admixtures. Kelly Ball Test. This is a simple field test consisting of the determination of the indentation made by 15 cm diameter metal hemisphere weighing 13.6 kg when freely placed on fresh concrete.

A Simple Guide to Concrete Cube Testing - QEM Solutions

Fresh Concrete: S EN 12350-1:2009 Sampling S EN 12350-2:2009 Testing Fresh oncrete, Slump Test S EN 206-1:2000 oncrete - Specification, Performance, Production and onformity Hard Concrete: S EN 12390-1:2000 Shape, Dimensions and other Requirements for Specimens and Moulds

Slump Test of concrete [5 Step by Step] Procedure

The concrete workability is the property of freshly mixed concrete which determines homogeneity, placed, combined, consolidated, and finished' as specified by ACI Standard 116R-90 or ACI 1990b.The w/c ratio, amount and type of aggregate and cement, admixtures, and weather conditions are the main factors that affect the workability of concrete.

Fresh concrete tests - SlideShare

Procedure: Penetrate the thermometer in fresh concrete sample at least 75mm. Leave the thermometer for 2 minutes in fresh concrete Take reading with accuracy of 0.5 C°. 10. C. Procedure: 11. Air Content Test: a. Definition: Air content …

Guidebook on non-destructive testing of concrete structures

inspection of concrete using the relevant NDT method; however, coverage is brief and does not present the whole range of NDT methods used for the NDT of concrete. Concrete has

Concrete Mixture PowerPoint PPT Presentations

Concrete is applied by using a mixing truck which readies the mixture and then pours it onto the ground. After that, the fresh concrete is then vibrated to flush out the air and also make sure that it is compact. Also, if you are looking for it then the Concrete construction in El Paso by Bomanite Concrete provides benefits to your dream project.

Ultrasonic Pulse Velocity Test | UPV Test

The Ultrasonic pulse velocity test is performed on concrete to assess the quality of concrete by passing ultrasonic pulse velocity through it as per IS: 13311 (Part 1) – 1992. The method consists of measuring the time of travel of an ultrasonic pulse passing through the concrete. The high velocity of ultrasonic pulse velocity and lower time ...

Compaction of Concrete - Boral

Page 3 of 7 > compaction of concrete Table 1 Characteristics and applications of immersion vibrators Diameter Recommended Average Radius of Rate of concrete of head 2frequency1 3,5amplitude action placement 4,5 (mm) (Hz) (mm) (mm) (m3/h per vibrator) Application 20–40 150–250 0.4–0.8 75–150 1–4 High slump concrete in very thin

Batching, Mixing, Transporting, and Handling Concrete ...

problems in both fresh and hardened concrete. Fig. 10-1. Control room for batching equipment in a typical ready mixed concrete plant. (69894) 179 HOME PAGE. Video. with a swinging discharge chute. Many stationary mixers have timing devices, some of which can be set