Viscometers - Viscosity - Accessories

Asphalt Institute Vacuum Viscometer: Cannon-Fenske Routine (CFR) BS/IP/SL U-tube: BS/U/M-Miniature: Zeitfuchs Cross-Arm: Modified Koppers Vacuum Viscometer: Cannon-Fenske Opaque (CFO) BS/IP/SL(S) BS/IP/MSL: Houillon: Cannon Manning Vacuum Viscometer

Asphalt Institute Vacuum Capillary Viscometer

Asphalt Institute Vacuum Capillary Viscometer. Asphalt Institute Vacuum Capillary Viscometers PSL-Rheotek. Suitable for measuring the dynamic viscosity of bituminous binders. Nominal overall length 245 mm. Calibrated in accordance with EN 12596 and ASTM D2171. Specifications:

Award Winners - Asphalt Institute

Vytautas "Vyt" P. Puzinauskas is widely known in the industry for his influence on the development of the viscosity grading system of asphalt. He designed the Asphalt Institute vacuum capillary viscometer and the Asphalt Institute—Puinauskas field viscometer used around the world.

Cannon AIVC-25 Asphalt Institute Vacuum Calibrated ...

Cannon AIVC-25 Asphalt Institute Vacuum Calibrated Viscometer, 42 to 800 Poise Viscosity Range, Size 25: Science Lab Viscometers: Amazon: Industrial & Scientific

Cannon AIVC-100 Asphalt Institute Viscometer Calibrated ...

This vacuum-calibrated viscometer meets the ASTM International D2171 standard for testing asphalt viscosity. A viscometer, also called a viscosimeter, is an instrument used to measure the friction caused by the relative motion of a Newtonian fluid and a known surface, and is usually expressed in units of poise (P), centipoise (cP), pascal ...

CANNON Asphalt Institute Vacuum Viscometers

The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometers are provided with a certificate of calibration and instruction sheet.

VISCOSITY TEST OF BITUMEN (IS 1206-PART-2) - CivilBlog.Org

Although Asphalt Institute vacuum viscometer and Modified Koppers vacuum viscometer can also be used, the following refers to Cannon-Manning vacuum viscometer only. Complete Absolute Viscosity Testing Equipment conforming to IS:1206 (Part 2) Method for Testing Tar and Bitumen Materials: Determination of Absolute Viscosity with the following ...

Products - biolab.tr

Biolab was established in 1987 as a group company within the United Engineering Co. Ltd. in Ankara, Turkey. In 1992, company has become an independent supplier and retailer of …

Asphalt Institute Vacuum Viscometer - Humboldt Mfg

Asphalt Institute Vacuum Viscometer Designed for measurement of highly-viscous materials, such as asphalt cement at 60°C (140°F), viscometer contains a graduated capillary instead of timing bulbs. Applicable to materials with a viscosity range of 0.036 …

Vacuum Viscometers - Matest

120 to 2400. B088-28. 360 to 8000. B088-29. 1200 to 24000. B088-30. 3600 to 80000. Note: to measure the viscosity with the Cannon-Manning viscometers, the B088-01N bath, the B088-05N holder and asphalt institute vacuum viscometer are also needed. Request information.

CANNON Automated Viscometers

Show. 5 10 15 20 25. per page. Quick Shop. CAV 4.1. 9725-D35. CAV 4.1 Single-Bath Benchtop Kinematic Viscometer. The CAV 4.1 replaces CANNON's trusted, …

Capillary Viscometer at Thomas Scientific

Asphalt Institute Vacuum, Cannon Aivc Series Viscometers Cannon Instrument Calibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer ...

Asphalt & Bitumen - PSL Rheotek

Viscosity testing of Asphalt and Bitumen may be carried out in a Reverse Flow Viscometer Tube or a Vacuum Viscometer tube. PSL Rheotek manufactures the full range of asphalt and bitumen tubes in the United Kingdom. Types include Aspahlt Institute, Cannon-Manning Vacuum, BSU Reverse Flow and Zeitfuchs. For vacuum viscometry, we recommend the use ...

Bitumen - Accessories - Tamson Instruments

Cannon Manning Vacuum Viscometer, Size number 12 Send e-mail for price. Cannon Manning Vacuum Viscometer, Size number 13 Send e-mail for price. Cannon Manning Vacuum Viscometer, Size number 14 Send e-mail for price. Asphalt Institute Vacuum …

Temperature-Viscosity Data on Asphalt Cements

The Saybolt-Furol and Brookfield viscometers give data which check quite well with those obtained by the Cannon-Manning vacuum-type capillary viscometer. 2. Kinematic viscosity limits 50 to 60 percent higher at 2 7 5° F than those prescribed by the Asphalt Institute were developed from measurements madein the capillary viscometer. 3.

Asphalt Institute Vacuum, Cannon Aivc Series Viscometers

We Believe You Are Important, How Can We Help? Log In or Create a Profile. We Believe You Are Important, How Can We Help? 1.800.345.2100

Viscosity Test For Bitumen Pdf - Recent Posts, rithillel

Although Asphalt Institute vacuum viscometer and Modified Koppers vacuum viscometer can also be used, the following refers to Cannon-Manning vacuum viscometer only. Note: Only the Cannon-Manning viscometer tubes need to be imported at this time, the remaining equipment such as bath and vacuum system are available in India.

Home page [cannonic-test.epicorcommerce]

DVR-1000/DVR-1500 Digital Vacuum Regulators; TE-1500 Sub-Zero Constant Temperature Bath; TE-3000 Sub-Zero Constant Temperature Bath; Flash Point Testers; Densitometers; Other Physical Property Testers; Manual Glass Viscometers. Asphalt Institute Vacuum Viscometer (Reversed Flow) BS/IP/MSL Miniature Suspended Level Viscometer

Dynamic Viscometers | Controls Group

Description. Cannon-Manning and Asphalt Institute vacuum viscometers. Used for determining the viscosity of bitumen at 60°C. Supplied complete with calibration certificate. For determining the dynamic viscosity all the above viscometers have to be introduced in the 81-B0116/A Viscometer bath by the appropriate Holder: 81-B0117/H1 for Cannon ...

Asphalt Institute Vacuum Viscometer, Cannon Instrument | VWR

The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materialsCalibrated with clear markings, the capillary viscometers support visual viscosity measurements of liquids. The direct or reverse flow styles have respectively positioned reservoirs to calculate the time it takes a specific fluid quantity to flow through the capillary.

Dynamic Viscometers - Controls Group

Cannon-Manning and Asphalt Institute vacuum viscometers Used for determining the viscosity of bitumen at 60°C. Supplied complete with calibration certificate. For determining the dynamic viscosity all the above viscometers have to be introduced in the 81-B0116/A Viscometer bath by the

China Asphalt Bitumen Vacuum Capillary Method Viscosity ...

2. Automatic control of temperature and vacuum degree. 3. Automatic timer 4. Capillary viscometer: 5. Asphalt Institute Vacuum Viscometers 6. NO.25 to NO.800R 7. Asphalt Bitumen Petroleum Dynamic Viscosity Test Viscometer

Viscosity of Asphalts by Vacuum Capillary

6.1 Viscometers, capillary-type, made of borosilicate glass, annealed, suitable for this test are as follows: 6.1. i Cannon-Manning Vacuum Viscometer (CMVV), as described in Appendix X1. 6.1.2 Asphalt Institute Vacuum Viscometer (AIVV), as de- scribed in Appendix X2. 6.1.3 Modijied Koppers Vacuum Viscometer (MKVV), as

B088-34 Asphalt Institute Vacuum Viscometers - Matest

Asphalt Institute Vacuum Viscometers. ( Bitumen ) EN 12595. ASTM D2170. AASHTO T201. To determine the viscosity of bitumen at 60°C. Supplied complete …

Capillary Viscometers | VWR

Description: The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials,10791-384EA,10791-392EA,10791-386EA,10791-404EA,10791-402EA,10791-382EA,10791-396EA Cannon-Fenske Routine Viscometer, Cannon Instrument Company

ASTM D 2171-01 …

ASPHALT INSTITUTE VACUUM CAPILLARY VISCOMETER (AIVV) X2.1 Scope X2.1.1 The Asphalt Institute vacuum capillary viscometer (AIVV)7,8 is available in seven sizes (Table X2.1) from a range from 4.2 to 580 000 Pa · s (42 to 5 800 000 P). Sizes 50 through 200 are best suited to viscosity measurements of asphalt cements at 60°C (140°F). X2.2 ...

Manual Glass Viscometers - Interactive Specialists in ...

1. asphalt institute vacuum viscometer (reversed flow) 2. bs/ip/msl miniature suspended level viscometer 3. bs/ip/rf u-tube reversed flow viscometer 4. bs/ip/sl suspended level viscometer 5. bs/u/m miniature viscometer (transparent) 6. bs/u-tube viscometer (transparent) 7. cannon-fenske opaque viscometer (reversed flow) 8. cannon-fenske routine viscometer 9.

ASTM D2171 _Asphalt_RF___ …

ASTM D2171 _Asphalt_RF、、,,。

Viscometers | ICL Calibration

Vytautas "Vyt" P. Puzinauskas is widely known in the industry for his influence on the development of the viscosity grading system of asphalt. He designed the Asphalt Institute vacuum capillary viscometer and the Asphalt Institute—Puinauskas field viscometer used around the world. He initiated research that established significant differences between the chemical and physical properties ...

price Cannon AIVC-25 Asphalt Institute Viscometer 4 ...

Cannon AIVC-25 Asphalt Institute Vacuum Calibrated Viscometer, 4 Product description The Cannon AIVC-25 vacuum-calibrated graduated capillary-style viscometer has a 42 to 800 poise (P) viscosity measuring range and is suitable for the measurement of highly viscous materials such …